Assistant Professor

Teodor Stanescu

PhD, MCCPM

Location
Princess Margaret Cancer Centre
Address
610 University Avenue, Toronto, Ontario Canada M5G 2M9
Clinical Interests
MRI-guided radiation therapy (MRIgRT), MRIgRT equipment design, MR image distortions, MRI-only radiation treatment planning, Dosimetry in external magnetic field (MR-linac systems), Magnetic shielding, Finite Elements Methods
Accepting
Please contact Faculty Member for more information

Qualification

  • BSc, University of Bucharest, Romania
  • MSc, University of Alberta
  • PhD, University of Alberta

Professional Memberships

  • Member, Canadian College of Physicists in Medicine, Radiation Oncology

Recent Publications

Stanescu T, Wachowicz K, Jaffray D: Characterization of tissue magnetic susceptibility-induced distortions for MRIgRT. Med Phys (in press)

Wachowicz K, Stanescu T, Fallone BG: Implications of tissue magnetic susceptibility-related distortion on the rotating magnet in an MR-linac design. Med Phys. 37(4): 1714-21, 2010.

Stanescu T, Jans H, Wachowicz K, Fallone BG: Investigation of a 3D system distortion correction method for MR images. J Appl Clin Med Phys. 11(1): 200-216, 2010.

Stanescu T, Kirkby C, Wachowicz K, Fallone BG: Developments in MRI-based radiation treatment planning. IFMBE 25: 821-824, 2009.

Fallone BG, Murray B, Rathee S, Stanescu T, Steciw S et al.: First MR images obtained during megavoltage photon irradiation from a prototype integrated linac-MR system. Med Phys. 36(6): 2084-88, 2009.

Kirkby C, Stanescu T, Fallone BG: Magnetic field effects on the energy deposition spectra of MV photon radiation. Phys Med Biol. 54(2): 243-257, 2009.

Stanescu T, Jans HS, Pervez N, Fallone BG: A study on the magnetic resonance imaging (MRI)-based radiation treatment planning of intracranial lesions. Phys Med Biol. 53(13): 3579-93, 2008.

Kirkby C, Stanescu T, Rathee S, Carlone M, Murray B, Fallone BG: Patient dosimetry for hybrid MRI-radiotherapy systems. Med Phys. 35(3): 1019-1027, 2008.

Schroeder C, Stanescu T, Rathee S, Fallone BG: Lag Measurement in an Active Matrix Flat Panel Imager. Med Phys. 31(5): 1-7, 2004.

Steciw S, Stanescu T, Rathee S, Fallone BG: Sensitivity reduction in biased amorphous selenium photoconductors. J Phys D: Appl Phys. 35: 2716-22, 2002.

 

Appointments

Assistant Professor, Department of Radiation Oncology, University of Toronto
Radiation Physicist, Princess Margaret Hospital/University Health Network
Affiliated Faculty, Guided Therapeutics, Techna Institute